Siya Habitats / Fire and life safety audit

Fire Audit Pro

The audit checklist for that building, derived from the code, captured on site without signal, and turned into the report from the same data.

Live
StatusLive.
Key requirements derived for a building Recording a non-compliant stair width with its clause The deficiency in the audit report with photo and corrective action
341Code-cited checkpoints
23Sections
208Distinct clauses
87Critical items
277Checkpoints for a G-2 factory
Derived, not filtered

The checklist is worked out for each building

Each check carries its own conditions. Give the app the building and it decides what applies, so an auditor never sees a question that cannot apply.

The building

Occupancy group, height band, basements, floor area, sprinklers.

The code edition

Two national editions held side by side, plus the binding Maharashtra schedule.

What applies

Only the checks whose conditions match, each with its clause and table.

On site, offline

Findings, measurements and photos captured at the point of observation.

The report

Produced from the same data, with every deficiency, clause and corrective action.

Key requirements, before the walk starts

Classification, travel distance, exit capacity, refuge areas, fire protection installations and water demand, each tagged with the clause or table it comes from.

The calculators encode real regulation

Exit widths, travel distances and sprinkler allowances follow the code's own rules, and return "not permitted" where the code does not allow a value at all. Where the two editions disagree, the difference is modelled rather than averaged away.

audit.siyahabitats.com

A finding, captured where it is seen

Mark the result, set the risk, note the location, measure against the limit, photograph it and write the corrective action, with no signal on the 14th floor.

audit.siyahabitats.com
Process and industrial safety

Factories need more than a building audit

For factory, storage and hazardous occupancies, Fire Audit Pro adds how the work inside is controlled, each check citing its clause of IS 14489:2018. Rules we do not yet hold are named and marked to verify, not guessed.

Work permitsContractorsChemicalsStorage vesselsStaticPressure plantFire teamEmergency plan
277Checkpoints for a G-2 factory
29Process safety checkpoints

Software assists.
A licensed person reviews and signs.

Run your next audit on it.

Open the app, or ask us to walk your team through a building.

FAQ

Questions people ask

What is Fire Audit Pro?

Fire Audit Pro is a web app for fire and life safety auditors. It builds the checklist for a specific building from the code, works on site without mobile signal, and produces the audit report from the same data.

How many checks does Fire Audit Pro cover?

Fire Audit Pro holds 341 code-cited checkpoints across 23 sections, drawn from 208 distinct clauses, with 87 marked critical. A Process and Industrial Safety section covers factory, storage and hazardous occupancies; a G-2 factory gets 277 checkpoints.

Does Fire Audit Pro work offline?

Yes. It is offline-first. Findings and photos are captured at the point of observation with no signal, and the report renders without a network connection.

Which codes does Fire Audit Pro use?

It holds two editions of the national code side by side and a rule pack transcribed from the binding Maharashtra schedule, with every row stamped with its gazette page. Process safety checks cite IS 14489:2018 and the applicable state and central rules, each named in the report.

Does Fire Audit Pro certify a building?

No. It records what was observed against each clause and produces the report. Software assists; a licensed person reviews and signs.